Steel Beam Lateral-Torsional Buckling (AISC 360 F2)

The moment an unbraced compression flange allows before it buckles sideways, below the plastic moment.

Run the calculator

Example

You enter

You get

Checked against published worked examples from: AISC.

Details, formula, and sources

ScopeAISC F2 grades the unbraced length against Lp = 1.76 ry sqrt(E/Fy) and the F2-6 Lr; between them Mn falls linearly, beyond Lr the elastic Fcr governs. A W18x50 braced every 10 ft drops from 421 to 360 kip-ft, and at 20 ft to 200 - less than half the braced number, the cliff that forces a brace or a heavier shape. Doubly-symmetric compact I-shapes, entered Cb. A design aid, not the engineer of record's stamped design.

Formula or tableMp = Fy Zx; Lp = 1.76 ry sqrt(E/Fy); Lr per AISC Eq. F2-6 (c = 1); Lb <= Lp: Mn = Mp; Lp < Lb <= Lr: Mn = Cb[Mp - (Mp - 0.7 Fy Sx)(Lb - Lp)/(Lr - Lp)] <= Mp; Lb > Lr: Fcr = Cb pi^2 E/(Lb/rts)^2 sqrt(1 + 0.078 Jc/(Sx ho)(Lb/rts)^2), Mn = Fcr Sx <= Mp. ASD = Mn/1.67; LRFD = 0.90 Mn. (E = 29,000 ksi)

Source and editionThe AISC 360-22 Section F2 lateral-torsional buckling provisions for a doubly-symmetric compact I-shape bending about its strong axis (Lp, the Eq. F2-6 Lr, the linear inelastic branch, and the Eq. F2-4 elastic critical stress with c = 1), by name; E = 29,000 ksi and the Omega_b = 1.67 / phi_b = 0.90 factors are named constants.

Free accessAISC 360 is free to read at aisc.org (Specification for Structural Steel Buildings); the shape properties are in the AISC Steel Construction Manual tables.

What governsEstimate. AHJ and licensed professional govern.

API field namesfy, zx, sx, ry, rts, j, ho, lb_ft, cb, lp_ft, lr_ft, mn_kipft, ma_kipft, phi_mn

Related tools