Coaxial Cable Attenuation

Total coax attenuation over a run, end-of-run signal level.

Run the calculator

Example

You enter

You get

Checked against published worked examples from: Belden / CommScope loss curves (by name).

Details, formula, and sources

ScopeTotal coax attenuation over a run, end-of-run signal level, or the maximum run for a target level (Belden / CommScope loss curves).

Formula or tableloss_dB = loss_per_100ft(type, frequency) * length / 100; end level = source - loss; inverse max run = 100 * (source - target) / loss_per_100ft.

Source and editionCoaxial-cable attenuation from the per-100-ft loss at frequency (loss = per-100-ft * length/100), per the cable manufacturer's published loss curves (Belden / CommScope) and the standard CATV/CCTV/SDI practice, by name; first-principles.

Free accessFirst-principles attenuation. The per-100-ft loss is type- and frequency-specific and user-supplied or a flagged default; the manufacturer's datasheet governs.

What governsEstimate. AHJ and licensed electrician govern. Verify against the NEC edition adopted in your jurisdiction.

API field namesmode, loss_per_100ft_db, length_ft, source_level, total_loss_db, end_level