Differential-Pressure Flow Meter (Orifice / Venturi)

Liquid flow through an orifice plate, venturi, or flow nozzle, from the differential pressure across it.

Run the calculator

Example

You enter

You get

Checked against published worked examples from: DP flow meter (larger line cross-check).

Details, formula, and sources

ScopeQ = Cd A2 sqrt(2 dP / (rho (1 - beta^4))), with beta = bore/pipe ID. Flow tracks the SQUARE ROOT of dP. Cd ~ 0.61 square-edge orifice, 0.98 venturi, 0.97 flow nozzle (editable) -- a venturi passes far more at the same dP and recovers most of the pressure. A 2 in bore in a 4 in water line at 1 psi (Cd 0.61) flows 75 gpm; the same at Cd 0.98 (venturi) flows 121 gpm. Enter dP in psi (1 psi = 27.7 in w.c.) and fluid density (water 62.4 lb/ft^3). Incompressible liquid only; a gas needs a separate expansion factor Y, and a precise Cd comes from ISO 5167 / the meter calibration. A field/sizing estimate; the calibrated meter governs.

Formula or tableQ = Cd A2 sqrt( 2 dP / (rho (1 - beta^4)) ); A2 = pi/4 d^2 (throat area); beta = d/D (bore/pipe-ID ratio); the 1 - beta^4 term is the velocity-of-approach factor. Incompressible liquid.

Source and editionThe differential-pressure primary-element (orifice / venturi / flow-nozzle) flow equation; ISO 5167 defines the precise discharge coefficient Cd and installation, but the Bernoulli equation itself is public physics, cited by name.

Free accessThe Bernoulli DP-flow equation is first-principles fluid mechanics; a typical Cd (0.61 orifice, 0.98 venturi, 0.97 nozzle) is editable and the meter's own calibration governs the exact value.

What governsEstimate. AHJ and licensed professional govern.

API field namespipe_id_in, bore_in, dp_psi, cd, fluid_density_lb_ft3, flow_gpm, beta_ratio