Stored-Grain Aeration Fan Airflow

The fan airflow to cool or dry stored grain.

Run the calculator

Example

You enter

You get

Details, formula, and sources

required CFM = rate x bushels, with the ~15/rate cooling-front rule. Aeration cooling (0.1-0.25 cfm/bu) is a different job from natural-air drying (0.5-1.0). Static pressure rises steeply with depth and fan power grows ~fourfold when the rate or depth doubles, so a fan sized on cfm/bu alone stalls in a tall bin.

required_cfm = rate_cfm_per_bu x bushels; cooling_hours = 15 / rate_cfm_per_bu (per cooling front).

Stored-grain aeration fan airflow (MWPS / university extension; Shedd airflow-resistance curves), by name.

The cfm-per-bushel airflow relation and the cooling-front rule are public MWPS / extension results; the fan selection at the design static pressure governs.

Estimate. AHJ and licensed professional govern.