Manual J Heating Load (Simplified)

Simplified heating load estimate.

Run the calculator

Example

You enter

You get

Checked against published worked examples from: ACCA Manual J residential heating-load identity.

Details, formula, and sources

Formula or tableHeating load = U×A×ΔT for walls, ceiling and windows + U×A×0.5ΔT for the floor + infiltration sensible (1.08 × CFM_inf × ΔT). Simplified estimator only; ACCA Manual J 8th ed. is the code-compliant method.

Source and editionACCA Manual J, 8th edition. NOAA NCEI heating design temperatures by location.

Free accessACCA Manual J licensed. NOAA design temps free at ncei.noaa.gov.

What governsEstimate. AHJ and licensed mechanical contractor govern. ACCA Manual J / D / S supersede rules of thumb.

API field namesfloor_area_ft2, wall_area_ft2, window_area_ft2, ceiling_area_ft2, insulation_level, window_type, outdoor_design_F, indoor_design_F, conductive_BTU_hr, infiltration_BTU_hr, total_BTU_hr, tons