SEER and EER Conversion

Bidirectional SEER / EER rating conversion on the NREL House Simulation Protocols relation EER = -0.02 SEER^2 + 1.12...

Run the calculator

Example

You enter

You get

No published worked example is on file for this calculation. It is checked against a hand-worked derivation of its method and an independent reference test.

Details, formula, and sources

ScopeBidirectional SEER / EER rating conversion on the NREL House Simulation Protocols relation EER = -0.02 SEER^2 + 1.12 SEER: SEER 16 is about EER 12.8, not the 14.3 a flat 1.12 ratio gives. The nameplate rating governs.

Formula or tableEER = BTU/hr ÷ W (steady state at AHRI 95 °F outdoor / 80 °F indoor). SEER weights cooling capacity over an AHRI 210/240 seasonal bin profile. SEER2 / EER2 add return-static loading per the 2023 federal test procedure.

Source and editionAHRI 210/240-2023 by name. DOE 10 CFR 430 (federal energy-conservation standards) by section.

Free accessAHRI 210/240 licensed; DOE 10 CFR 430 free at ecfr.gov.

What governsEstimate. AHJ and licensed mechanical contractor govern. ACCA Manual J / D / S supersede rules of thumb.

API field namesvalue, from, SEER, SEER2_estimate