Seismic Design Story Drift and Allowable Limit (ASCE 7-22 12.8.6 / 12.12)

Amplified seismic story drift against its allowable limit.

Run the calculator

Example

You enter

You get

Checked against published worked examples from: FEMA / BSSC.

Details, formula, and sources

ScopeAmplified drift delta_x = Cd delta_xe / Ie against the allowable delta_a = drift coefficient x story height (commonly 0.020 hsx). Cd 5.5, delta_xe 0.5 in, 144 in story -> 2.75 in vs 2.88 in allowable, OK at 0.955 utilization; a softer frame at 0.6 in fails. A design aid; the engineer of record governs.

Formula or tabledelta_x = Cd delta_xe / Ie; delta_a = drift_ratio x hsx; util = delta_x / delta_a.

Source and editionThe ASCE 7-22 12.8.6 amplified design story drift and the 12.12 allowable story-drift limit, by name.

Free accessThe Cd amplification of the elastic drift and the tabulated allowable drift are the published ASCE 7 drift-check procedure.

What governsEstimate. AHJ and licensed professional govern.

API field namesdelta_xe_in, cd, ie, hsx_in, drift_ratio, delta_x, delta_a, util

Related tools