Sprinkler Precipitation Rate

The precipitation rate a valve zone applies.

Run the calculator

Example

You enter

You get

Checked against published worked examples from: Rain Bird.

Details, formula, and sources

Scopein in/hr (PR = 96.3 x zone gpm / zone area), the number that sets the runtime and the reason spray heads and rotors never share a valve. Head flows come from the manufacturer's nozzle chart; this is a design-rate estimate, not a system audit (irrigation-uniformity audits the installed result).

Formula or tableprecip_in_hr = 96.3 x zone_gpm / zone_ft2 (the 96.3 constant = 231 in^3/gal / 144 in^2/ft^2 x 60 min/hr spreads 1 gpm over 1 ft^2).

Source and editionFirst-principles precipitation-rate relation with the Irrigation Association design references and the Rain Bird / Hunter design manuals (by name); no edition cycle.

Free accessThe precipitation-rate relation and the 96.3 constant are public irrigation-design practice. The nozzle chart and the matched-precipitation rule are in the manufacturer's design manuals.

What governsEstimate. AHJ and licensed professional govern.

API field nameszone_gpm, zone_ft2, precip_in_hr