Column Web Panel-Zone Shear (AISC 360 J10.6)
The AISC 360-16 J10.6 panel-zone shear strength of a moment-connection column web, both branches.
Example
You enter
- Column yield Fy (ksi) 50
- Column depth dc (in) 14
- Column web tw (in) 0.5
- Column flange width bcf (in) 14.5
- Column flange thickness tcf (in) 0.75
- Beam depth db (in) 24
- Beam flange tf (in) 1
- Sum of beam flange moments (kip-in) 5500
- Column shear Vcol (kip) 40
- Panel-zone deformation in the frame analysis? no
You get
- Basic strength Rn (J10-9) 210 kip
- Design phiRn (used branch) 189 kip (basic)
- Panel-zone demand / doubler 199 kip - DOUBLER PLATE needed
Details, formula, and sources
Basic Rn = 0.60 Fy dc tw (J10-9) and the flange-stiffened bonus (J10-11, allowed only when panel-zone deformation is in the analysis), against the joint demand, with a doubler-plate flag. The moment-frame joint often fails here first.
Rn_basic = 0.60 Fy dc tw (J10-9); Rn_pz = Rn_basic [1 + 3 bcf tcf^2/(db dc tw)] (J10-11); phiRn = 0.90 Rn; demand = sum(Mf)/(db - tf) - Vcol.
The AISC 360-16 Section J10.6 panel-zone (web) shear strength, Eq. J10-9 and J10-11, by name.
AISC 360 is available through AISC; the J10.6 panel-zone provisions are published design equations.
Estimate. AHJ and licensed professional govern.
Field names used by the API: fy_ksi, col_depth_dc_in, col_web_tw_in, col_flange_bcf_in, col_flange_tcf_in, beam_depth_db_in, beam_flange_tf_in, demand_moment_kin, col_shear_kip, pz_in_analysis, rn_basic_kip, phi_rn_kip, demand_kip
- Two-branch strength basic J10-9 unless panel-zone deformation is in the analysis, then the J10-11 flange bonus appliesAISC 360-16 J10.6
- Low-axial case Pr <= 0.4 Pc; a higher axial load applies a further reduction not included hereAISC 360-16 J10.6