Thermal Imager Delta-T Reference

Typical surface-temperature differentials for moisture, insulation, and electrical hotspots.

Open the reference

Reference

Scenarios

Checked against published worked examples from: IICRC S500 + ASHRAE-bundled thermal-delta-T scenarios.

Details, formula, and sources

Formula or table(reference page; no compute) Thermal-imager delta-T interpretation: compare inspected component temperature against an unloaded reference of the same construction; a surface 1 °C or more BELOW a dry reference of the same construction flags moisture (evaporative cooling); 5-10 °C differences flag an active issue per IR-imaging engineering practice.

Source and editionASTM C1153 (Standard Practice for Location of Wet Insulation in Roofing Systems) by name; FLIR / Fluke published thermography training materials.

Free accessASTM licensed; training overviews free at flir.com / fluke.com / infraredtraining.com.

What governsEstimate. AHJ and licensed professional govern.