Greenhouse Thermal Screen Energy Saving

Builds the envelope area and UA for a gable house, applies the screen's UA reduction over the heating season.

Run the calculator

Example

You enter

You get

Details, formula, and sources

Builds the envelope area and UA for a gable house, applies the screen's UA reduction over the heating season, and reports fuel saved and simple payback. The worked house saves $3,432 a year on a 3.36 year payback. The light the screen costs does not appear in that payback: open on a light level, not a clock.

UA = envelope area x glazing U-factor; seasonal saving = UA difference x average night temperature difference x deployed hours, divided by the heating plant efficiency.

The screen manufacturer's published UA reduction on the installed configuration, and the site's own fuel and weather records, govern.

Public envelope arithmetic; UA reductions are published by screen manufacturers.

Estimate. AHJ and licensed professional govern.

Field names used by the API: house_width_ft, house_length_ft, gutter_height_ft, ridge_height_ft, glazing_u_factor, screen_ua_reduction_pct, season_nights, night_hours, night_temp_difference_f, plant_efficiency_pct, fuel_price_per_therm, screen_cost_per_sqft, envelope_sqft, envelope_to_floor_ratio, roof_share_pct, base_ua, screened_ua, heat_saved_btu, therms_saved, annual_saving, screen_cost, payback_years