Greenhouse Thermal Screen Energy Saving

Builds the envelope area and UA for a gable house, applies the screen's UA reduction over the heating season.

Run the calculator

Example

You enter

You get

No published worked example is on file for this calculation. It is checked against a hand-worked derivation of its method and an independent reference test.

Details, formula, and sources

ScopeBuilds the envelope area and UA for a gable house, applies the screen's UA reduction over the heating season, and reports fuel saved and simple payback. The worked house saves $3,432 a year on a 3.36 year payback. The light the screen costs does not appear in that payback: open on a light level, not a clock.

Formula or tableUA = envelope area x glazing U-factor; seasonal saving = UA difference x average night temperature difference x deployed hours, divided by the heating plant efficiency.

Source and editionThe screen manufacturer's published UA reduction on the installed configuration, and the site's own fuel and weather records, govern.

Free accessPublic envelope arithmetic; UA reductions are published by screen manufacturers.

What governsEstimate. AHJ and licensed professional govern.

API field nameshouse_width_ft, house_length_ft, gutter_height_ft, ridge_height_ft, glazing_u_factor, screen_ua_reduction_pct, season_nights, night_hours, night_temp_difference_f, plant_efficiency_pct, fuel_price_per_therm, screen_cost_per_sqft, envelope_sqft, envelope_to_floor_ratio, roof_share_pct, base_ua, screened_ua, heat_saved_btu, therms_saved, annual_saving, screen_cost, payback_years