UV Required Intensity or Contact Time

The inverse of the UV-dose tile: from a target dose, solve the operand you are missing - leave intensity blank for the required contact time (dose / intensity), or leave time blank for the required intensity (dose / time). A 40 mJ/cm^2 target at 10 mW/cm^2 needs 4 s of contact; at a fixed 8 s it needs a 5 mW/cm^2 lamp. USEPA UV Disinfection Guidance; the validated reactor dose and the state primacy agency govern compliance.

Run the calculator

Formula and source

required_time_s = target_dose_mj_cm2 / intensity_mw_cm2; or required_intensity_mw_cm2 = target_dose_mj_cm2 / exposure_time_s (mW.s/cm^2 = mJ/cm^2).

USEPA UV Disinfection Guidance Manual (EPA 815-R-06-007) by name, the inverse of dose = intensity x time; no edition cycle.

Audience

This tile is built for water operators and the adjacent professions in the Water and Wastewater Operations group. The interactive calculator runs entirely in your browser. No account, no fee, no advertising, no tracking.

Related tools

Posture

Rough Logic answers the math question the working professional asks on the job. The site is a calm, fast, ad-free, account-free, ever-free reference. It does not interpret code. It does not replace the licensed professional. It does not store your inputs. The Authority Having Jurisdiction governs all installations and inspections.