Well Drawdown and Specific Capacity
Drawdown, specific capacity (GPM per ft), and recommended pump-setting depth.
Example
You enter
- Static water level (ft below ground) 50
- Pumping water level (ft below ground) 80
- Discharge rate (GPM) 30
- Pump-setting offset below pumping level (ft) 20
You get
- Drawdown 30
- Specific capacity 1
- Recommended pump setting 100 ft below ground
Details, formula, and sources
With a marginal-well flag below 0.5 GPM/ft. Per AWWA A100 and USGS OFR 02-197.
Drawdown (ft) = pumping water level - static water level. Specific capacity (GPM/ft) = discharge / drawdown. Recommended pump setting (ft) = pumping level + offset (default 20 ft below the pumping level).
AWWA A100 (Water Wells) standard; USGS well-testing methods (USGS Open-File Report 02-197).
awwa.org for the A100 TOC; pubs.usgs.gov for the USGS report.
Estimate. Operator of record and primacy agency govern.
Field names used by the API: static_level_ft, pumping_level_ft, discharge_gpm, pump_offset_ft, drawdown_ft, specific_capacity_gpm_ft, pump_setting_ft
- Specific-capacity floor < 0.5 GPM/ft flagged as a marginal wellAWWA A100 / USGS field practice
- Pump-setting offset 20 ft below the pumping level (default; user overrides)well-pump field practice