Wood Diaphragm Unit Shear and Chord Force (SDPWS)

The flexible wood diaphragm as a deep horizontal beam.

Run the calculator

Example

You enter

You get

Details, formula, and sources

The end reaction V = wL/2, the maximum unit shear v = wL/(2b) the sheathing nailing must carry, the moment wL^2/8, and the chord force T = C = M/b the perimeter members resolve it into. A 192 x 120 ft roof at 516 plf runs 413 plf of unit shear -- the published WoodWorks value -- and 19.8 kip of chord force; narrow the diaphragm to 60 ft and both exactly double. Simple-span flexible (tributary) distribution; collectors, deflection, and openings are separate. A design aid, not a substitute for the engineer of record's stamped lateral design.

V = w L / 2; v = w L / (2 b); M = w L^2 / 8; chord T = C = M / b.

The AWC Special Design Provisions for Wind and Seismic (SDPWS) simple-span flexible-diaphragm deep-beam model, as compiled in the AWC/APA engineered-wood-diaphragm design guides, by name.

AWC SDPWS is viewable free of charge through AWC's online reader; the deep-beam w L / (2 b) arithmetic is public.

Estimate. AHJ and licensed professional govern.

Field names used by the API: w_plf, l_ft, b_ft, v_end_lb, v_plf, m_ftlb, chord_kip