Drinking Fountain Heights and Count (2010 ADA Standards 211, 602)

One fountain is never enough: 211.2 wants TWO, one for a seated person and one for a standing person, and a single unit substitutes only if it complies with BOTH -- which is what a bi-level hi-lo is. The two heights are opposite ends with a real gap between them: the wheelchair spout is 36 in MAXIMUM and the standing spout 38 in minimum, so the single fountain set at a comfortable-looking 37 in satisfies NEITHER. Two location rules get skipped -- 15 in minimum from the vertical support and 5 in maximum from the front edge INCLUDING BUMPERS, which is how bumpers added later push a compliant fountain out of tolerance.

Run the calculator

Formula and source

count: no fewer than two units, one complying with 602.1 through 602.6 and one with 602.7, unless a single unit complies with both. Heights: wheelchair spout outlet 36 in maximum; standing spout outlet 38 in minimum to 43 in maximum, leaving a dead band from 36 to 38 in that satisfies neither. Location: spout 15 in minimum from the vertical support and 5 in maximum from the front edge including bumpers; water stream 4 in high minimum.

2010 ADA Standards for Accessible Design, 211.2, 602.4, 602.5, 602.6, and 602.7. A US federal standard in the public domain, quoted directly.

Audience

This tile is built for plumbers and the adjacent professions in the Carpentry and Construction group. The interactive calculator runs entirely in your browser. No account, no fee, no advertising, no tracking.

Related tools

Posture

Rough Logic answers the math question the working professional asks on the job. The site is a calm, fast, ad-free, account-free, ever-free reference. It does not interpret code. It does not replace the licensed professional. It does not store your inputs. The Authority Having Jurisdiction governs all installations and inspections.