Lavatory Height and Bathtub Clearance (2010 ADA Standards 606, 607)

Two rules short enough to skip and specific enough to fail a remodel that measured fine everywhere else. The lavatory limit of 34 in is to the front of the HIGHER of the rim or the COUNTER -- so a vessel sink or a thick stone top fails a fixture that was specified correctly, and the fixture was never the problem. Metering faucets must stay open 10 SECONDS, longer than most ship set. And the clearance in front of a tub runs the LENGTH of the tub at 30 in wide, extending 12 in PAST the head-end wall where there is a permanent seat -- so a 60 in tub needs 72 in of floor, which is the part that gets drawn short.

Run the calculator

Formula and source

lavatory: the front of the higher of the rim or the counter surface is 34 in maximum above the finish floor; hand-operated metering faucets remain open 10 seconds minimum. Bathtub: clearance in front extends the length of the tub and is 30 in wide minimum, extending 12 in beyond the wall at the head end where a permanent seat is provided - so the required clearance length = tub length + 12 in with a seat, and the tub length without.

2010 ADA Standards for Accessible Design, 606.3, 606.4, 606.5, 607.2, and 607.3. A US federal standard in the public domain, quoted directly.

Audience

This tile is built for plumbers and the adjacent professions in the Carpentry and Construction group. The interactive calculator runs entirely in your browser. No account, no fee, no advertising, no tracking.

Related tools

Posture

Rough Logic answers the math question the working professional asks on the job. The site is a calm, fast, ad-free, account-free, ever-free reference. It does not interpret code. It does not replace the licensed professional. It does not store your inputs. The Authority Having Jurisdiction governs all installations and inspections.