Return Activated Sludge (RAS) Flow Rate

The return-pump rate from the solids mass balance.

Run the calculator

Example

You enter

You get

Details, formula, and sources

Q_RAS = Q x MLSS / (RAS_SS - MLSS), plus the return ratio. The clarifier only thickens sludge 3-4x, so RAS_SS is capped -- cranking the pump to chase a higher MLSS floods the clarifier and washes solids over the weir. The mass balance, not the pump maximum, sets the rate.

Q_RAS = Q x MLSS / (RAS_SS - MLSS); ras_ratio = Q_RAS / Q x 100.

RAS flow from the activated-sludge solids mass balance (WEF MOP / Sacramento activated-sludge manuals), by name.

The solids-balance return-rate relation is a public wastewater-operations result; the settleability and clarifier performance govern the actual set point.

Estimate. AHJ and licensed professional govern.

Field names used by the API: plant_flow_mgd, mlss_mg_l, ras_ss_mg_l, q_ras_mgd, ras_ratio_pct