Smoke Ejector / Ventilation CFM (NFPA 1500)

Required CFM for a target air-change rate, fans needed, time to one air change.

Run the calculator

Example

You enter

You get

Details, formula, and sources

Required CFM for a target air-change rate, fans needed, time to one air change, and the exhaust-to-entry opening ratio for negative-pressure ventilation. SOP and incident command govern.

Required CFM = volume × ACH / 60. Fans = ceil(required CFM / per-fan rating). Time to one air change = volume / actual CFM. Exhaust-to-entry opening ratio drives PPV efficiency (1:1 to 1.5:1).

NFPA 1500 §8.5 (apparatus and equipment) by name; IFSTA Essentials of Fire Fighting ventilation chapter by name.

NFPA 1500 read-only at nfpa.org/freeaccess; NFA materials free at usfa.fema.gov.

Estimate. AHJ and licensed fire protection engineer govern.

Field names used by the API: length_ft, width_ft, height_ft, target_ach, fan_cfm, exhaust_opening_ft2, entry_opening_ft2, cfm_required, fans, time_to_one_change_min, opening_ratio