Water Hammer Arrestor Sizing
PDI WH-201 designation from total fixture units.
Example
You enter
- Total fixture units (WSFU) 30
- Branch length (ft) 25
- Pipe internal diameter (in) 1
You get
- Designation AA-B
- WSFU total 30
- Pipe diameter (in) 1
- Pre-charge (set air side, system depressurized) 60
Checked against published worked examples from: PDI.
Details, formula, and sources
Formula or tablePDI WH-201 method: size A–F selected by the branch's total fixture units (WSFU); a branch over 20 ft is flagged for an additional unit at each fixture group.
Source and editionPDI WH-201 by name.
Free accessPDI specifications licensed; manufacturer data sheets (Sioux Chief, Watts) free at each manufacturer site.
What governsEstimate. AHJ and licensed plumber / gas fitter govern. Verify against the IPC / IFGC edition adopted in your jurisdiction.
API field nameswsfu, length_ft, internal_diameter_in, designation, wsfu_total, pipe_diameter_in, precharge_psi
- Closure speed assumption fast-closing solenoid valvePDI WH-201 by name