141 calculators. Every one runs in your browser. Free, no account.
Tools in this group
- Pipe Sizing - Water supply by fixture units; drainage by DFU.
- Friction Loss - Hazen-Williams for water; Darcy-Weisbach for gas.
- Pipe Volume - Gallons per foot by diameter.
- Pump Sizing - Required head and flow.
- Static Pressure Loss in Piping - Static pressure loss along a pipe run.
- Gas Pipe Sizing - BTU capacity by pipe size, length, gas type.
- Drainage Slope - 1/4 inch per foot rule and variants.
- Pressure Conversion - PSI, head feet, inches of water column, kPa, bar.
- Backflow Reference - Common backflow scenarios and preventer types.
- Water Hammer Arrestor Sizing - PDI WH-201 designation from total fixture units.
- Hot Water Recirc Pump Head - Pump head from pipe length, fittings, target flow.
- Hot Water Recirc Loop Sizing (ASPE) - Per ASPE Data Book Vol. 4 Ch. 6: derives heat-loss rate, required GPM from set-point delta.
- Septic Tank Sizing - Minimum tank gallons from bedrooms or daily flow.
- Trap Arm Length - Maximum trap arm length by pipe diameter and slope.
- Pipe Thermal Expansion - Linear expansion (in) for copper, PEX, PVC, CPVC, steel.
- Tankless Water Heater GPM - Achievable flow from burner kBTU and inlet/outlet temperatures.
- Gas Leak Rate (Orifice) - Estimated leak rate from orifice diameter and upstream pressure.
- Gas Leak Equivalent Hole Diameter - The equivalent orifice (hole) diameter behind a measured gas leak rate.
- Stormwater Rational Method - Peak stormwater runoff from a drainage area, in cfs and gpm.
- Max Tributary Drainage Area for an Allowable Flow - The largest tributary catchment an inlet, pipe, or outlet rated for an allowable flow can accept.
- Manning's Equation Drainage Slope - Self-cleansing slope and slope to carry target flow at half-full.
- Circular Pipe Partial-Flow Depth and Velocity (Manning) - How deep a gravity pipe actually runs at a given flow, and how fast the water moves at that depth.
- Manning Pipe Capacity (Full-Bore Gravity Flow) - The discharge a circular gravity pipe carries flowing full at a given slope.
- Drainage Invert Elevation, Drop, and Cover - Invert-out, total fall, and cover over a gravity run from its slope and length.
- Hydronic Radiant Floor Loop Sizing - The tube footage from the heated area and on-center spacing.
- Hydrostatic Test Pressure and Hold - Test pressure (1.5x water / 1.25x gas) and recommended hold time.
- Grease Trap Sizing - Volume from peak flow, retention, and loading factor; PDI G101 cited.
- Grease Interceptor Flow Capacity - The peak fixture flow an existing grease interceptor is rated to serve.
- Glycol Freeze Protection Mix - Glycol percent and concentrate gallons from manufacturer freeze-point curves.
- Hydronic Expansion Tank - Required diaphragm tank volume from system volume, fill, and relief pressures.
- Backflow Preventer Pressure Loss - Pressure loss interpolated from manufacturer-published curves.
- Water Hammer Pressure Surge (Joukowsky) - Wave celerity from pipe-fluid coupling, pressure surge dP = rho × a × dV, and rapid-closure flag against 2L/a.
- Pump Operating Point - Intersection of bundled pump curve with H_sys = H_static + k Q^2; SVG plot + numeric table at sample flows.
- Septic Drainfield Trench Length - Required absorption area and trench linear feet from design daily flow and the application rate set by your local code.
- Septic Drainfield Capacity (Flow / Bedrooms) - The design flow and bedroom count a drainfield supports, from the trench length a lot can fit.
- Pipe Thermal Expansion and Loop Sizing - Linear expansion plus the guided-cantilever expansion-loop leg L_loop = sqrt(3 × E × D × dL / S_a).
- Water Heater Recovery Rate - Recovery gph and AHRI first-hour rating from input rating, efficiency, and temperature rise.
- Solar Thermal Collector Output - The useful heat a flat-plate solar thermal collector delivers.
- Water Heater Input for a Target Recovery - The burner or element input needed to sustain a target recovery rate.
- Water Heater Thermal Expansion Tank - Potable closed-system expansion volume and required tank size from heater capacity, temperatures, and incoming pressure.
- Sanitary Drain DFU Sizing - Total drainage fixture units from a fixture list and the minimum pipe size for a horizontal branch, vertical stack.
- Trap Primer Sizing - Primer / distribution-unit count, annual water use.
- Backflow Assembly Sizing Screen - Hazard-driven assembly selection (RP required for any high / health hazard per IPC 312).
- Cross-Connection Air Gap (IPC 608.15.1) - The minimum air gap for the most positive backflow protection there is.
- Hydronic Fill Pressure (Static Height) - The cold-fill pressure a hydronic loop needs to lift water to its highest point and keep air out.
- Solder and Flux per Sweat-Joint Takeoff - Solder for a copper rough-in from the joint count.
- Pipe Insulation and Jacket Material Takeoff - The mechanical insulator's material list.
- Freeze-Protection Heat-Trace Cable and Circuit - The heat-trace cable and wattage a run needs to stay above freezing.
- Trap-Seal Protection Check - Within-limit pass/fail and percent of the permitted trap-to-vent distance used.
- Water Meter Sizing from Peak Demand - Adequate/undersized verdict, percent of the meter's normal-flow rating used, and the headroom.
- Water Thermal-Expansion Volume - Expanded water volume gained on heating from bundled NIST water-density points.
- DWV Vent-Stack DFU / Length Check - Pass/fail of a vent stack against the adopted code's permitted DFU and developed-length table values.
- Low-Pressure Fuel-Gas Pressure Drop (Spitzglass) - Pressure drop (in. w.c.) and velocity for low-pressure fuel gas via the Spitzglass equation.
- Fuel-Gas Pipe Capacity (Spitzglass) - The most gas a bore carries within an allowable pressure drop.
- Septic Pump / Dose Tank Volume - Net dose per cycle, pumped volume per cycle and per day.
- Septic Tank Pump-Out Interval - Years between tank pump-outs from the working volume, household size, and a per-capita sludge/scum accumulation rate.
- Septic Tank Size for a Target Pump-Out Interval - The septic tank working volume that puts a target number of years between pumpings.
- Septic LPP Orifice Flow and Squirt Height - Per-orifice flow, orifice count, and system flow for a low-pressure-pipe septic lateral.
- Septic LPP Squirt Head for a Target Orifice Flow - The squirt head (residual pressure) that produces a target per-orifice discharge in an LPP drainfield.
- Mixing / Tempering Valve Blend Temperature - Blended delivery temperature, mix ratio, or hot flow for a tempering valve, with a scald-limit flag.
- Well Pressure-Tank Drawdown and Sizing - Usable drawdown, runtime per cycle, and short-cycle flag for a well pressure tank.
- Pipe Velocity and Erosion Check - Flow velocity (v = 0.4085*gpm/d^2) and the copper erosion-corrosion verdict, or the max flow for a velocity ceiling.
- Probable Peak Demand (WSFU to GPM) - Hunter's-curve probable peak flow in GPM from total water-supply fixture units, for flush-tank or flush-valve systems.
- Water-Supply Pressure Budget - Available residual at the critical fixture after elevation, meter, backflow, and friction losses.
- Roof Drain and Leader Sizing - Storm flow in GPM from roof area and design rainfall.
- Overflow Scupper Sizing (Weir Flow) - Secondary (overflow) scupper as a rectangular weir.
- Scupper Width for a Required Overflow Flow - The scupper width for a required overflow flow at a design head.
- Sewage Force-Main Scour Velocity - Whether a sewage force main runs fast enough to keep solids from settling out.
- Dry Well / Infiltration Trench Sizing - The size of a stone-filled dry well or infiltration trench (soakaway) that stores runoff and soaks it into the ground.
- Stormwater Detention Volume (Modified Rational) - The detention storage a site needs to hold its peak runoff down to the allowable release rate.
- Sump / Ejector Basin Drawdown and Cycle Check - Drawdown volume, run and fill times, cycles per hour.
- Gas Appliance Connected Load (CFH) - Total connected BTU/hr and the cubic feet per hour that feeds gas-pipe sizing.
- Water-Heater T&P Relief and Discharge - Checks a water heater's T&P valve against its input and sizes the discharge pipe.
- Pipe Hanger Spacing and Count - Maximum support spacing for a pipe material, size, and orientation from IPC 308.5, and the hanger count for a run.
- Water Softener Sizing - Compensated hardness, daily grain load, days between regenerations.
- Pipe Cold Spring (Cut-Short) - Free thermal growth, the cold-spring gap to cut the run short.
- Pipe Inert Purge Volume and Time - Inert (nitrogen) purge volume and time for a pipe run while brazing or purging a gas / process line.
- Leach-Field / Trench Drainrock Volume - Washed drainrock for a septic leach field from the trench layout.
- Hydronic System Water and Glycol Volume - Fill volume of a hydronic system and its water / glycol split.
- PEX Home-Run Manifold Port and Tubing Takeoff - PEX home-run manifold ports and tubing for one line per fixture.
- Time of Concentration (Kirpich) - The storm duration stormwater-rational needs but never computes.
- Time of Concentration (TR-55 Velocity Method) - Time of concentration by the NRCS TR-55 velocity method, summing the travel time through sheet flow.
- Curve Number Runoff Depth (SCS/NRCS) - Runoff DEPTH from a storm by the NRCS Curve Number method (TR-55 Chapter 2).
- TR-55 Graphical Peak Discharge - Peak flow from a curve-number watershed by the NRCS TR-55 Graphical Peak Discharge method (Chapter 4).
- Composite Curve Number (Impervious Area) - The composite curve number for a developed area of mixed land use and impervious cover (NRCS TR-55 Chapter 2).
- TR-55 Detention Storage Volume - Approximate detention-basin storage by the NRCS TR-55 Chapter 6 method.
- Culvert Headwater by Inlet Control (HDS-5) - How high the water ponds at a culvert entrance under inlet control.
- Governing Culvert Headwater (HDS-5) - The governing culvert headwater - the GREATER of inlet and outlet control - and which one wins.
- Culvert Headwater by Outlet Control (HDS-5) - Culvert headwater under OUTLET control, where the barrel and the tailwater set the head.
- Governing Box Culvert Headwater (HDS-5) - The governing headwater for a rectangular BOX culvert - the GREATER of inlet and outlet control.
- Box Culvert Headwater by Outlet Control (HDS-5) - Headwater for a rectangular BOX culvert under OUTLET control, where the barrel and the tailwater set the head.
- Box Culvert Headwater by Inlet Control (HDS-5) - Headwater for a rectangular BOX culvert under INLET control, where the entrance sets the head.
- Orifice Discharge Flow - The flow through a sharp-edged hole that sizes a detention-pond outlet, a tank drain, or a restrictor plate.
- Orifice Diameter for a Target Flow - The diameter that passes a target flow under a steady head.
- Tank Drain Time (Falling-Head Orifice) - How long a tank takes to empty through an orifice, integrating the falling head.
- Open-Channel Froude Number, Regime, and Critical Depth - Whether an open channel runs tranquil or rapid, which manning-slope and weir-flow never tell you.
- Trapezoidal Channel / Swale Capacity (Manning) - Flow in a TRAPEZOIDAL channel - the shape every real swale, roadside ditch, and lined channel takes.
- Rectangular Channel Normal Depth (Manning) - The Manning normal (uniform-flow) depth of a rectangular channel.
- Hydraulic Jump: Sequent Depth and Energy Loss - Where supercritical flow leaps to a deeper tranquil depth below a chute or culvert.
- Open-Channel Specific Energy and Alternate Depth - The specific-energy diagram of an open channel.
- Velocity Head and Dynamic Pressure - The pressure a moving fluid carries by virtue of its speed alone.
- Flow Continuity Velocity at a Size Change - The velocity a flow picks up when the pipe changes size.
- Bernoulli Total Head (Pressure + Velocity + Elevation) - Total head H = P/gamma + V^2/(2g) + z (ft of fluid), the mechanical energy per unit weight.
- Thrust Block Bearing Area at a Pipe Bend (AWWA M41) - The thrust a pipe bend throws, and the bearing area a block needs to take it.
- Max Line Pressure for a Thrust Block (AWWA M41) - The highest test/surge pressure a thrust block of a given bearing-face area restrains at a bend.
- Water Main Chlorination Dose - The chlorine to charge a newly installed or repaired water main the AWWA C651 way.
- Well Shock-Chlorination Dose - The household bleach to shock-chlorinate a private well from the casing diameter and standing water column.
- High-Altitude Appliance Input Derate - The derated maximum input for a gas appliance at altitude per the NFPA 54 / IFGC high-altitude provision.
- Natural-Gas / Propane Conversion (Input and Orifice) - What changes when an appliance is converted between natural gas and propane.
- Gas Appliance Connection Check (IFGC 408.4 / 409.5 / 411.1.3.1) - Three rules meet at the last three feet of gas piping, and one category cuts across all of them.
- Wobbe Index (Fuel-Gas Interchangeability) - The single number that governs fuel-gas interchangeability.
- Medical Gas System Demand and Diversity (NFPA 99) - The first sizing step for an oxygen, medical-air, nitrous, or vacuum main.
- Storage Water-Heater Sizing (First-Hour Rating) - Whether a storage water heater meets the household peak-hour demand.
- Water Service Pressure, PRV, and the Closed System (IPC 604.8 / 607.3) - A causal chain people walk into one step at a time.
- Drainage Cleanout Layout (IPC 708) - Three triggers put cleanouts in a drain and they ADD, so counting from any one comes out low.
- ADA Grab Bar Layout and Blocking Load - Where the grab bars go in an accessible toilet or bathing room.
- Air Admittance Valve Installation Check (IPC 918) - The AAV is sold as the thing that saves you a vent through the roof, and IPC 918.7 says plainly that it does not.
- Vent Terminal Height, Frost Closure, and Location (IPC 903) - Three independent rules land on the same pipe, and satisfying two is not compliance.
- Accessible Toilet Compartment Sizing (2010 ADA Standards 604.8) - Two compartments can be owed, and the second is triggered by an OR that gets read as an AND.
- Shower Compartment Size (IPC 417.4) - Two compliance paths, each with TWO conditions, and area alone satisfies neither.
- Plumbing Fixture Clearances (IPC 405.3.1) - The bathroom rough-in check, in four numbers.
- Flash Steam Percentage Across a Pressure Drop - The fraction of condensate that re-boils to steam when it drops across a trap from a high pressure to a lower one.
- Steam Main Size from Flow and Velocity - Sizes a steam main by mass flow against an allowable velocity.
- Steam Main Capacity from Size and Velocity - How much steam an existing Sch 40 main carries within an allowable velocity.
- Steam Trap Condensate Load and Required Capacity - Running condensate load, and the trap capacity it needs at the operating differential.
- Steam Boiler Surface Blowdown (Cycles of Concentration) - The continuous surface blowdown a steam boiler needs to hold its dissolved solids below the limit, by a TDS mass balance.
- Steam Orifice / PRV Capacity (Napier) - Choked steam through an orifice or PRV by Napier's formula.
- Radiator EDR to Heat Output - The heat a cast-iron radiator delivers from its EDR (Equivalent Direct Radiation, sq ft) rating.
- Boiler Horsepower, Steam Output, and EDR - The ABMA / ASME boiler ratings from a gross output.
- Steam PRV Orifice Area for a Required Capacity (Napier) - The orifice / seat area a required relief capacity needs.
- ASME UG-27 Shell Thickness (Joint Efficiency and Corrosion) - The ASME Section VIII shell thickness. t = PR/(SE - 0.6P) for a cylinder, PR/(2SE - 0.2P) for a sphere.
- ASME UG-32 Formed-Head Thickness (Ellipsoidal, Hemispherical, Torispherical) - The ASME Section VIII head thickness, for ellipsoidal, hemispherical, and torispherical heads.
- Pipe Pressure Rating and Required Wall (ASME B31.1) - The ASME B31.1 internal-pressure relation both directions.
- Filled Pipe Support Load per Hanger - The load each pipe hanger carries: pipe, fluid, and insulation over its spacing.
- Minimum Hanger Rod Diameter from Load (MSS SP-58) - The smallest threaded rod whose MSS SP-58 safe load clears the per-hanger load.
- Condensate Return Line Size From the Flash Steam - The return line size from the FLASH steam that re-boils off the condensate at the lower return pressure, not the liquid.
- Branch Saddle Cutback Template (Pipe-on-Pipe) - The saddle contour ordinates for a branch pipe notched to sit on a run pipe for a welded branch connection.
- Reducer Centerline Offset and Invert Continuity - The centerline offset = (large OD - small OD) / 2 and which surface stays continuous through a size change.
- Flange Pressure-Temperature Rating (ASME B16.5) - The maximum allowable working pressure of a flange CLASS at a service temperature.
- Branch Connection Reinforcement (Area Replacement, ASME B31.1) - Whether a branch opening cut into a pressurized run needs a reinforcing pad.
- Expansion Joint / Loop Guide Spacing (EJMA 4D/14D) - Where the first two guides go so an expansion joint or loop compresses instead of buckling sideways.
Other trades
- Electrical - 236 calculators
- HVAC - 165 calculators
- Water Damage and Mold Restoration - 53 calculators
- Carpentry and Construction - 550 calculators
- Fire-Ground Engineering - 58 calculators
- Cross-Trade Utilities - 117 calculators
- Knowledge References - 15 calculators
- Trucking and Logistics - 43 calculators
- Mechanic - Auto, Marine, Aviation - 154 calculators
- Agriculture and Forestry - 78 calculators
- Water and Wastewater Operations - 66 calculators
- Stage and Live Production - 40 calculators
- Kitchen and Food Service - 33 calculators
- Field, Backcountry, and SAR - 35 calculators
- Historical Reference Data - 1 calculators
- Accounting, Tax, and Small-Business - 31 calculators
- Bench Science and Laboratory Math - 27 calculators
- Real Estate - 35 calculators
- Educators and K-12 - 29 calculators
- Rigging and Heavy Lift - 33 calculators