Trap-Seal Protection Check

Within-limit pass/fail and percent of the permitted trap-to-vent distance used.

Run the calculator

Example

You enter

You get

Details, formula, and sources

With a self-/induced-siphonage flag when the vent is inadequate. Per IPC §1002 / UPC §1002; the permitted maximum is user-supplied from the adopted table.

Pass if the developed trap-to-vent distance <= the code-permitted maximum for the drain diameter; percent used = distance / permitted x 100; siphonage risk when the vent is inadequate or the trap seal is below 1 in.

IPC §1002 / UPC §1002 trap-seal-protection and trap-to-vent distance provisions, by name.

Free read-only at codes.iccsafe.org; the AHJ-adopted edition governs.

Estimate. AHJ and licensed plumber / gas fitter govern. Verify against the IPC / IFGC edition adopted in your jurisdiction.

Field names used by the API: developed_distance_ft, table_max_ft, trap_seal_in, percent_used