Scupper Width for a Required Overflow Flow

The inverse of the overflow-scupper-sizing tile: the scupper width for a required overflow flow at a design head, from the rectangular weir Q = 3.33 L H^1.5. L = Q / (3.33 H^1.5) suppressed, or + 0.2 H for a contracted (narrow) scupper. 118 gpm at a 3.5 in head needs a 6.0 in opening (6.7 in contracted). Round the width UP; head is at the blocked-primary condition (IPC 1108 / FM Global). The code and roof-loading check govern.

Run the calculator

Formula and source

L = Q / (3.33 H^1.5) (suppressed); L = Q / (3.33 H^1.5) + 0.2 H (contracted); Q_cfs = required_gpm / 448.8; L and H in ft, width reported in inches.

The rectangular (Francis) weir capacity of an overflow scupper (secondary roof drainage per IPC 1108 / FM Global), by name, solved for the width.

Audience

This tile is built for plumbers and the adjacent professions in the Plumbing and Gas group. The interactive calculator runs entirely in your browser. No account, no fee, no advertising, no tracking.

Related tools

Posture

Rough Logic answers the math question the working professional asks on the job. The site is a calm, fast, ad-free, account-free, ever-free reference. It does not interpret code. It does not replace the licensed professional. It does not store your inputs. The Authority Having Jurisdiction governs all installations and inspections.