Mixing / Tempering Valve Blend Temperature

Blended delivery temperature, mix ratio, or hot flow for a tempering valve, with a scald-limit flag.

Run the calculator

Example

You enter

You get

Details, formula, and sources

T_blend = (Qh*Th + Qc*Tc)/(Qh+Qc); inverse hot fraction = (T_target - Tc)/(Th - Tc); hot:cold ratio = (T_target - Tc)/(Th - T_target).

First-principles mixing energy balance for blending hot and cold potable water; the delivery-temperature limits follow the ASSE 1017 (master tempering) and ASSE 1016/1070 (point-of-use scald-guard) device standards and the IPC/UPC scald provisions, by name.

Public first-principles energy balance. The listed mixing valve and the AHJ govern the installed setpoint.

Estimate. AHJ and licensed plumber / gas fitter govern. Verify against the IPC / IFGC edition adopted in your jurisdiction.

Field names used by the API: mode, hot_temp_F, cold_temp_F, hot_gpm, cold_gpm, blend_temp_F, percent_hot