Drying Goal
Target indoor GPP based on outdoor conditions.
Example
You enter
- Outdoor temperature (°F) 80
- Outdoor RH (percent) 70
- Indoor temperature (°F) 72
- Margin (GPP below outdoor) 10
You get
- Outdoor GPP 108
- Target indoor GPP 98
- Target indoor RH 83 %
Checked against published worked examples from: IICRC.
Details, formula, and sources
Formula or tableTarget indoor GPP = outdoor GPP - drying-gradient. IICRC S500-2021 'normal-drying' guidance: target 5-15 GPP below outdoor; psychrometric chart drives the dry-bulb / RH set point that delivers the target.
Source and editionIICRC S500-2021 (Standard for Professional Water Damage Restoration) by name.
Free accessIICRC standards licensed; principles free in published water-damage-restoration training literature.
What governsEstimate. AHJ and licensed professional govern.
API field namesoutdoor_temperature_F, outdoor_RH_percent, indoor_temperature_F, margin_GPP, outdoor_GPP, target_indoor_GPP, target_indoor_RH_percent
- Drying gradient 5-15 GPP below outdoor (S500 normal-drying band) unless user suppliesIICRC S500-2021